Interview Question After Completed Electrical Engineering.
INDEX
1. Wire size
2. Two way
switch connection
3. Intermmeadate
switch connection
4. Tests to be made on a new electrical installation
befor it is switched on to the mains ?
5. How one light
control in Five plase?
6. Why Earthing
is require Transformer Neutral?
7. How is a Amp
if load 2000W?
8. What is a
Cos@
9. Star Delta
Connection
10. Why Neutral
not present in the Delta Connection
11. Why Star/Delta
Startor use for ?
12.Typs of
Pannel
13.Internal
Connection of DB
14. If maximum
No circuit B7 which No of Circuit
Connected in the DB?
15.Type of
Earth?
16. How to
Earthing Test?
17. Corridor
Lighting?
18. Type of
house wiring?
19.Types of Wire
Joint?
20.Type of Switch
21. Size of Gland?
22. Drawing Scale?
v 1.Wire Size
0.5, 0.75, 1.0, 1.5, 2.5, 4, 6, 10, 16, 25, 35, 50, 70, 95 Sq mm.
Cable size
0.5, 0.75, 1.0, 1.5, 2.5, 4, 6, 10, 16,
25, 35, 50, 70, 95, 120, 150, 185, 240, 300, 400, 500, 630, 800, 1000 Sq mm.
v 2.Two Way Switch
?
Two way switch use for one light control
two or more place .
v 3.Intermediate Switch ?
It is use
for Corridors lighting and one
light Control more then two place.
v 4. Tests to be made on a new electrical installation
befor it is switched on to the mains ?
i. Insulation resistance test between
Conductor and earth.
Befor making
test , the conditions to be fulfilled
for the position of the main switch fuses, switches and other points should be
as under.
each final
sub circuit should have a resistance of at least 0.5 megaohms during the worst
condition .
a) The main
switch in off position.
b)The fuses
beyond the main switch should be in position i.e main fuse is taken out.
c) All
switches in ON position.
d) Lamp and
other equipment in their position.
ii. Insulation
resistance test between conductor.
The value
should not be less then 0.5 Megaohm and not more then one Mehaohm.
a) The
maiiin switch in OFF position.
b) The short
circuiting at the main switch not be done.
c) All
switch in ON position.
d) The fuses
beyond the main switch should be in position.
iii.
Testing of polarity.
iv.
Testing of Earth continuity path.
v. Earth resistance test.
v 5. How to
one light control four place ?
v 7. How is a Amp if load 2000W Single Phase ?
Single Phase
W=2000
W=VI
Cos@
I= W/V
Cos@ V=220 V
I
=2000/220X0.8 Cos @= 0.8
I= 11.36 Amp
3 Phase
I =
2000/1.732X440X0.8
I=3.28 Amp
v 8. What is Cos@?
Cos@
is a angels between the voltage and Current.
v
9. 9.Transformer
Star/Delta Connection.
v 10. Why Neutral
not present in the Delta Connection?
mainly two resons
i. Delta
connection circuit alredy closed.
ii. Not any common point.
v 11. Why Star/Delta Startor use for ?
Ia=(v-Eb)/Ra
If full
supply voltage is apply across the stationary armatures . It will draw a very
large current because
armatures resistantce is relabelety
small . This excessive current will blow out
the fuses an prior to that , it will damages
the commutator and brushes etc.
Star/Delta Starter connection
v 12.Typs of
Pannel ?
i. LT Panel ii. HT Panel
i. LT Panel .
a. Light
Control Panel b. Power
Factor Control Panel.
c.Motor
Control Center (MCC)
d. Power Control Center (PCC).
ii. HT Panel .
a. VCB
Panel .
v 13.
Internal Connection of DB ?
v
14. If maximum No circuit B7 Totals No of
Circuit Connected in the DB?
R1,Y1,B1............R5,Y5,B5..............R7,Y7,B7. =
3X7= 21 Circuit .
v 15. Type of Earth?
i. Plate Earth. ii. Pipe
Earth. iii. Rod Earthing. iv.
Strip or Wire Earthing. v.
Waterman Earthing.
v 16. How to Earthing Test?
a) By a
portable megger earth tester.
b) By an earth
loop tester.
c)By an
ohmmeter.
d) By the
viltmeter and ammeter using either DC or AC source.
Portabble Digital Magger Earth Tester.
v 17. Corridor Lighting?
v 18. Type of
house wiring?
i. Concealed
conduit wiring
ii.Surface conduit wiring
iii. Metal
sheathed wiring
iv.C.T.S or Batton wiring .
v.Wooden casin and capping wiring .
vi. Cleat wiring .
v 19.Types of Wire
Joint?
i.
Straight twist joint.
ii.Britanna joint.
iii.
Married joint.
iv.Scarf
joint.
v.Tee
joint.
vi.Duplex joint.
vii. Pigtail joint.
v 20. Type of Switch ?
i. One
way switch
ii. Two Way Switch.
iii.Two Way Center off Switch
iv. Double Pole Man Switch.
v. Bed
Switch.
vi. Push Button Switch.
vii. Intermediate Switch.
v 21. Size of
Gland ?
Cable(sq mm) |
Gland(mm) |
300 240 185 150 120 95 70 50 35 25 16 10 |
63 57 50 45 45s 38 70s 32 28 25 22 19 |
22. Drawing Scale?
Drawng Scale are Three types.
1.Reducing Scale 2. True Scale 3. Large
Scale.
Thanks you.